Model Number †BTU/Hour In 1000’s Kcal/Hour In 1000’s Number of Jets Dimensions Pipe Size Weight
Min Max Min Max Inches mm Inches mm Lbs. Kg.
C-20, C-21 5 10 1,25 2,5 2 3 x 1 77 x 25 1/4 8 1 ,45
C-30, C-31 7.5 15 1,85 3,75 3 2 3/4 dia. 70 dia. 1/4 8 1 ,45
C-40, C-41 10 20 2,5 5,0 4 3 5/8 dia. 92 dia. 3/8 10 1 ,45
C-60, C-61 15 30 1,85 7,5 6 4 1/4 dia. 108 dia. 3/8 10 1 1/2 ,7
C-80, C-81 20 40 5,0 10,0 8 5 1/4 dia. 133 dia. 3/8 10 2 ,9
C-90, C-91 22.5 45 5,85 11,25 9 5 1/4 dia. 133 dia. 3/8 10 2 ,9
L-40 10 20 2,5 5,0 4 8 1/2 x 1 216 x 25 3/4, 1 20,25 1 1/2 ,7
L-50 12.5 25 2,125 6,25 5 9 3/8 x 1 238 x 25 3/8, 1/2, 3/4 10, 15, 20 2 ,9
C-8-S 20 40 5,0 10,0 8 4 3/4 x 4 3/4 121 x 121 3/8 10 2 ,9
C-10-S 25 50 6,25 12,5 10 6 3/4 x 6 3/4 171 x 171 3/8 10 2 1/2 1,1
CL-80, CL-81 20 40 5,0 10,0 8 2 3/4 x 10 70 x 254 3/8 10 2 1/2 1,1
CL-90, CL-91 25 50 6,25 12,5 10 2 3/4 x 12 70 x 305 3/8 10 3 1/2 1,6
CL-100, CL-101 30 60 7,5 15 12 2 3/4 x 14 70 x 356 3/8 10 4 1,8
† SC-151 37 75 9,25 18,5 15 4 x 13 102 x 330 1/2 15 3 1/2 1,6
SC-600 15 30 1,85 7,5 6 2 3/4 x 5 70 x 127 3/8, 1/2 10, 15 1 1/2 ,7
‡ SCP-600 15 30 1,85 ,85 7,5 6 2 3/4 x 5 70 x 127 3/8, 1/3 10, 15 2 ,9
† C-120 30 60 7,5 15 12 7 dia. 178 dia. 3/8 10 3 1,4
† C-150 37.5 75 9,375 18,75 15 8 3/4 dia. 212 dia. 3/8 15 4 1,8
† C-190 47.5 95 11,875 23,75 19 8 3/4 dia. 212 dia. 1/2 15 4 1/2 2,0
† C-220 55 110 13,75 27,50 22 10 dia. 254 dia. 1/2 15 4 1/2 2,0
† ‡‡ C-240 60 120 15 30 24 10 1/2 dia. 267 dia. 1/2 20 6 1/2 2,9
† C-270 67 135 16,755 33,50 27 10 1/2 dia 267 dia 3/4 20 6 1/2 2,9
† C-360 90 180 22,5 45 36 13 dia. 330 dia. 3/4 20 9 1/2 4,3
† ‡‡‡ C-440 110 220 27,5 55 44 15 dia. 381 dia. (2) 1/2 (2) 15 14 (7 ea.) 6,4 (3,2 ea.)

*With 651 jets on Natural, Manufactured, and Mixed (Town) Gases, BTU input is as shown. On LP Gas with 651 jets, reduce maximum input to 3,500 per jet.

†These burners have bottom openings only.

‡SCP-600 differs from SC-600 having a pilot boss tapped for 668-S pilot jet.

‡‡C-240 same as C-270 except with 3 fewer jets in the inner portion.

‡‡‡C-440 is two separate castings.

Slotted Cap and Flat Flame Burner Unit Specifications
SLOTTED CAP and FLAT FLAME JET SPECS
Type Jet BTU/Hr.Per Jet Kcal/Hr.Per Jet FLAME DIMENSIONS
Total Height Total Width
In Inches In mm In Inches In mm
651 2,500 to 5,000 625 to 1,250 1 1/2 to 2 1/2 38 to 63 1 to 2 25 to 51
654 † 7,500 1,875 3 76 3 76

654 jet is fired over 5,000 BTU/Hr and up to 7,500 BTU/Hr, it must be spaced at.